Avitech Rainier-4a User Manual Page 47

  • Download
  • Add to my manuals
  • Print
  • Page
    / 49
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 46
Page N°47
Rainier – AAP Example
1. “*” “1” “Enter” <used to initiate communication with the Rainier>
2. ZC 010000 border 000255000 <set group 1 border color to dim
green>
3. ZF 010101 1 <maximize window 1 on module 1 in group 1 to full
screen>
4. ZF 010101 0 <resume window 1 on module 1 in group 1 back
from full screen>
5. ZM 010000 10 <set all modules in group 1 to 1600x1200 at 60hz>
6. ZP 000000 load 1.GP1 <load preset 1 for all modules>
7. ZT 000000 2 1 6 <turn on tally 2 for all windows and set the tally
color to pink>
8. ZX 000000 "Input 1“ <set all labels to display Input 1>
9. ZJ 020000 G <Implement auto gain for all windows in group 2>
10. “*” “0” “Enter” <terminate communication with the Rainier>